PIONEER ENERGY
CMS Comprehensive Logging Instrument

PIONEER-CMS is an internationally advanced comprehensive logging system. The instrument is integrated with many advanced technologies including the pioneering explosion-proof CAN bus technology, fast chromatography technology, measurement while drilling (MWD) technology, on-site geological analysis instrument joint application technology, etc., making it truly become a comprehensive on-site information interpretation and evaluation center. 


PIONEER-CMS comprehensive logging instrument has been widely recognized by logging personnel, which not only serves major domestic oil fields, but also is widely applied in over ten countries and regions including the US, Russia, India, Pakistan, truly becoming a national brand.

Features


  • Differential chromatography: solving the problem of identifying true and false oil and gas displays caused by oil mixing, adding organic additives, and drilling fluid pollution;
  • Explosion-proof CAN bus transmission: simplified sensor installation, convenient expansion, automatic fault diagnosis, and self-protection; 
  • Remote transmission: real-time information transmission between well pads and remote bases independent of communication methods 
  • Dual hot backup: double insurance is added to ensure the normal operation of logging work and data security 
  • Well pad information center: open database structure and WITS standard interface to achieve integration with third-party data 
  • Paperless recording: paperless recording and logging process reproduction that cannot be tampered with throughout the process, and direct generation of PDF documents; 
  • Professional abnormality warning: a professional system for engineering abnormality prediction to reduce engineering accidents, greatly reducing operational risks and ensuring the safety of drilling;
  • Comprehensive evaluation of oil and gas: integrated with various information including engineering, gas logging, geological analysis, etc., greatly improving the compliance rate of interpretation and evaluation of oil, gas, and water layers 
  • Rich application software to withstand international testing⸺Chinese, English, and Russian versions that meet international service requirements

Technical Indicators

 


Power Unit
  • Flameproof transformer
  • UPS Uninterruptible power supply
  • Instrument Room Safety Indicators

Input voltage     380V (480V, 440V, 220V Optional)
Input frequency 50Hz
Output voltage 380V±5%
Output frequency 50Hz

input voltage 220V±10%
input frenquency 35-65 Hz
Output voltage 220V±2%
Output Frenquency 50±1Hz
Power-On Time ≥15 minutes


The insulation resistance between the phase line and the machine room grounding conductor is greater than 2M, and the instrument must be equipped with a good grounding device.

Gas Analyzer
  • Natural gas hydrocarbon component analyzer
  • Natural Gas Non-Hydrocarbon component analyzer

Analysis cycle
30, 90s (user-defined analysis of cycle time) 
Test component
C1~nC5
Minimum detection concentration
total hydrocarbon 1×10-6, hydrocarbon component 1×10-6
Measuring range
total hydrocarbon 1×10-6~1, hydrocarbon component 1×10-6~1
Methylethane separation degree
≥ 0.85, obvious separation under the condition of 1% methane mixture (C1/C2 300:1)
Noise
≤0.5% F.S/h
Baseline stability
≤1% F.S/h
Repeatability error
≤2.5% F.S


Measurement content
CO2
Minimum detection concentration
CO2 0.1% 
Measurement range
CO2 0.1%~100%
Baseline drift
1%/7d of full scale
Repeatability error
±5%


  • Sensors

Pump stroke sensor/rotary table speed sensor 
range: 0-1920 strokes/minute
Rotary table torque sensor
range: 0~6MPa
Riser pressure sensor
range: 0~42MPa
Casing pressure sensor
range: 0~68MPa
Hook hanging load sensor
range: 0~6MPa
Drilling fluid temperature sensor
range: 0~125 ℃
Drilling fluid density sensor
range: 0~3g/cm 
Drilling fluid conductivity sensor
range: 0~50ms/cm, 0~300ms/cm
Drilling fluid outlet flow sensor
range: 0~100% (relative flow
Drilling fluid pool volume sensor
range: 0~5m
Drawworks sensor
range: 0~9999, hook position setting: 0~50m
Hydrogen sulfide sensor 
range: 0~100ppm, response time: T80<30s


Geological instrument
  • Carbonate analyzer
  • Mudstone density tester
  • Fluorescence meter
  • Thermal vacuum distillation degasser

Measurement range
0~100% carbonate
Accuracy
1%


Measurement range
1~3g/cm3
Minimum sample weight
0.05g
Resolution
0.01g/cm3


Power suppl
220VAC、50Hz
Power
40W

Power supply
220VAC、50Hz
Heating powe
300W
System vacuum
≤1.3KPa
System tightness 
after the vacuum degree reaches 1.3KPa, visually check the vacuum gauge for a drop of no more than 0.26KPa within 2 hours after the gas valve is cut of
Mud bottle volume
250ml

Electric degasser
  • Degasser

working voltage three-phase 380VAC
Power
370W
Speed 
1400rpm
Explosion-proof grade
ExdIIBT4


Software system
  • software system

windows operating system
Chinese, English, Russian, and Spanish versions
Metric and English system and custom units conversion
Rich background application software


GET CONNECTED FOR ANY QUESTIONS.
  • Name
  • Email
  • Phone
  • Message
Submit