PIONEER ENERGY
WFS Well Plant Logging Instrument

Overview


    • WFS well plant logging instrument is a new generation of petroleum exploration and development equipment developed to meet the on-site logging needs of shale gas drilling based on years of accumulated professional technology, and relying on the advantages of the company’s scientific and technological talents and strong industrial foundation in Shanghai. It is leading in the overall design and manufacturing technology in China, and reaches the international advanced level. 


  • WFS well plant logging instrument uses a set of logging instruments to achieve simultaneous logging of two or more wells on site. It is not only equipped with a conventional fast chromatograph and a CAN bus data acquisition system, but also is equipped with wireless sensors and a wellhead chromatography system, fully meeting the logging tasks in the well plant operation mode.

Features 


    • A working area for logging personnel is available in the logging instrument room to make the working environment more comfortable. A chromatograph installed at the wellhead to reduce pipeline delay, and achieve faster gas measurement results. 


  • Wireless sensor systems to reduce field wiring and meet rapid installation in multiple wells Reduce on-site logging personnel and reduce logging costs. Dual servers at the well pad and base to meet the requirements of remote logging. 

Technical Indicators
  • Power Unit

  • Isolating transformer
  • UPS uninterruptible power supply
  • Instrument room safety indicators

Input voltage
380V (480V, 440V, 220V optional)
Input frequency
50Hz
Output voltage
380V±5%
Output frequency
50Hz


Input voltage
220V±10%
Input frequency
35~65Hz
Output voltage
220V±2%
Output frequency
50±1Hz
Power-on time
≥15min


the insulation resistance between the phase line and the machine room grounding conductor is greater than 2M, and the instrument must be equipped with a good grounding device

  • Gas analyzer

  • 3Q06 fast chromatograph
  • ChromWizard wellhead chromatograph
  • Wireless data transmission and support WITS data t

Analysis cycle
30, 90s (user-defined analysis of cycle time)
Test component
C1~nC5
Minimum detection concentration
total hydrocarbon 1×10-6, hydrocarbon
Measuring range
total hydrocarbon 1×10-6~1, hydrocarbon component 1×10-6~1
Methylethane separation degree
≥ 0.85, obvious separation under the condition of 1% methane mixture (C1/C2 300:1)
Noise
≤0.5% F.S/h
Baseline stability
≤1% F.S/h
Repeatability error
≤2.5% F.S 



Working area
positive pressure explosion-proof zone 1 and zone 2
Length x width x height (cm) 
(H)90×(W)80×(D)30
Weight
50kg (flameproof control box and positive pressure box are independent, with quick on site connection and installation)
Chromatography principle
catalytic combustion
Analysis cycle
60 seconds (C1-C5)
Minimum detection concentration of component
10ppm(C1)
Minimum detection concentration of total hydrocarbon
10ppm(C1)
Carrier gas
air
Degassing method
conventional degasser

Ambient temperature 
-20 - +60 ℃

  • Sensor

  • Sensor (CAN bus, 7W01 wireless)

Pump stroke sensor/rotary table speed sensor
range: 0-1920 strokes/minute
Rotary table torque sensor
range: 0~6MPa
Riser pressure sensor
range: 0~42MPa
Casing pressure sensor
range: 0~68MPa
Hook hanging load sensor
range: 0~6MPa
Drilling fluid temperature sensor
range: 0~125 ℃
Drilling fluid density sensor
range: 0~3g/cm 
Drilling fluid conductivity sensor
range: 0~50ms/cm, 0~300ms/cm
Drilling fluid outlet flow sensor
range: 0~100% (relative flow)
Drilling fluid pool volume sensor
range: 0~5m
Drawworks sensor
range: 0~9999, hook position setting: 0~50m 
Hydrogen sulfide sensor 
0~100ppm, response time: T80<30s 


 7W01 wireless sensor
  • 7W01 wireless sensor

Network nodes
64
Transmission distance
100m
Operating temperature
-30-60 ℃
Explosion-proof certification
wireless node: Ex ia IIC T4
Wireless host: Ex nA IIC T4
Battery powered continuous working time exceeds 3 months



Geological instrument
  • Carbonate analyzer
  • Mudstone density tester
  • Fluorescence meter
  • Thermal vacuum distillation degasser

Measurement range
0~100% carbonate
Accuracy
1%


Measurement range 
1~3g/cm3
Minimum sample weight
0.05g
Resolution
0.01g/cm3


Power supply
220VAC, 50Hz
Power
40W


Power supply
220VAC, 50Hz
Heating power
300W
System vacuum
≤1.3KPa
System tightness
after the vacuum degree reaches 1.3KPa, visually
check the vacuum gauge for a drop of no more than
0.26KPa within 2 hours after the gas valve is cut of
Mud bottle volume
250ml


Electric degasser
  • Electric degasser

Working voltage
three-phase380VAC
Power
370W
Speed
1400rpm
Explosion-proof grade
ExdIIBT4


Software system
  • Software system

windows operating system
Chinese, English, Russian, and Spanish versions
Metric and English system and custom units conversion
Rich background application software


GET CONNECTED FOR HELP
  • Name
  • Email
  • Phone
  • Message
Submit