BM-8860 Gas Chromatograph (Full EPC)

● Operation Display: 7-inch color LCD touchscreen, usable as a handheld controller.
● Temperature Control Zones: 8 channels; Temperature Control Range: 4℃ above room temperature to 450℃, Increment: 0.5℃; Accuracy: ±0.1℃
● Programmed Temperature Steps: 20 steps, Rate of Increase: 0.1~120℃/min

● Gas Path Control: Full-path EPC electronic pressure and flow control; selectable carrier gas and make-up gas types: He, H2, N2, and Ar; each carrier gas system can achieve constant pressure, constant flow, constant speed, programmed pressure, programmed flow rate, and programmed linear velocity gas control modes.


Measurement Range: 0~100 Psi (pressure...)

● Operation Display: 7-inch color LCD touchscreen, can be used as a handheld controller

● Temperature Control Zones: 8 channels; Temperature Control Range: 4℃ above room temperature to 450℃,

Increment: 0.5℃; Accuracy: ±0.1℃

● Programmed Temperature Ramp Steps: 20 steps, Ramp Rate: 0.1~120℃/min

● Gas Path Control: Full EPC electronic pressure and flow control, selectable carrier gas and make-up gas types: He, H2, 

N2, and Ar.


 Each carrier gas system can achieve constant pressure, constant flow, constant velocity, programmed pressure, programmed 

flow, and programmed linear velocity gas control modes.


Range: 0~100 Psi (pressure);


0~1000 mL/min (flow), Resolution: 0.001 Psi (pressure);


0.01 mL/min (flow); Maximum split ratio: 1:7500


● External Events: 8 channels; Auxiliary control output: 2 channels

● Injector Types: Packed column injection, capillary injection, six-port valve gas injection, automatic sampler

● Number of Detectors: 3 (maximum); FID, TCD, ECD, FPD, and NPD are optional

● Injection Start: Manual or automatic selectable

● Communication Interface: Ethernet: IEEE802.3, Acquisition signal rate: 1200Hz; with retention time locking.


Temperature Control Range: 4℃ above room temperature to 450℃ (adjustable in 1℃ increments)

Automatic ignition, capable of withstanding 100,000 ignition cycles


Carrier gas (column head pressure)Carrier gas: EPC electronic pressure and flow control, range: 0–100 Psi
Diversion and ventingFlow splitting: Maximum splitting ratio: 1:7500
Spacer purgingMaximum splitting ratio: 1:7500
Hydrogen flame ionization detector (FID)◆ Detection limit: ≤1×10⁻¹² g/S (n-hexadecane)
◆ Baseline noise: ≤2×10⁻¹⁴ A
◆ Baseline drift: ≤1×10⁻¹³ A/30min
◆ Linear range: ≥107
Electron Capture Detector (ECD)◆ Baseline noise: ≤0.03mV
◆ Baseline drift: ≤0.2mV/30min
◆ Linear range: ≥10³
◆ ≤5×10⁻¹⁴ g/ml (gamma-hexachlorocyclohexane-isooctane solution)
Flame photometric detector (FPD)◆ Detection limit: (S) ≤ 5 × 10⁻¹¹ g/s, (P) ≤ 1 × 10⁻¹² g/s (methyl parathion - anhydrous ethanol solution)
◆ Baseline noise: ≤3×10⁻¹³ A
◆ Baseline drift: ≤2×10⁻¹² A/30 min
injectorIt can support a maximum of 256 sample positions.